Protection For Telephone Line Circuit
A long time ago when telephones were so simple almost nothing could go amiss from an electrical point of view, Telecom operators installed surge protection on all telephone lines exposed to storm risks. Paradoxically, now that we are hooking up delicate and expensive equipment such as telephones filled with electronics, fax machines, (A)DSL modems, etc., this protection has disappeared.
However, if you have the good fortune to live in the countryside in a building served by overhead telephone lines, there’s an obvious risk of very high voltages being induced on the lines during thunderstorms. While we have lost count today of all of the modems, fax machines and other telephones that have been destroyed by a ‘bolt of lightning’, surprisingly you only have to invest a few pounds to get a remarkably efficient protection device like the one we are proposing here.
During a storm, often with lightning striking near a telephone line, the line carries transient voltages up to several thousands of volts. Contrary to the HV section of television sets or electrical fences, on which practically no current is running, in the case of lighting striking current surges of thousand of amps are not uncommon. To protect oneself from such destructive pulses, traditional components are not powerful or fast enough.
As you can see on our drawing, a (gas-filled) spark gap should be used. Such a component contains three electrodes, insulated from each other, in an airtight cylinder filled with rare gas. As long as the voltage present between the electrodes is below a certain threshold, the spark gap remains perfectly passive and presents an impedance of several hundreds of MW. On the other hand, when the voltage rises above this threshold, the gas is very rapidly ionized and the spark-gap suddenly becomes a full conductor to the point of being able to absorb colossal currents without being destroyed.
Protection Circuit Diagram For Telephone Line :
The one we are using here, whose size is of the same magnitude as an ordinary one watt resistor, can absorb a standardized 5,000 amps pulse lasting 8/20 ms! Since we are utilizing a three-electrode spark gap, the voltage between the two wires of the line or between any wire and ground, cannot exceed the sparking voltage, which is about 250 volts here. Such protection could theoretically suffice but we preferred to add a second security device made with a VDR (GeMOV or SiOV depending on the manufacturer), which also limits the voltage between line wires to a maximum of 250 volts.
Even if this value seems high to you, we should remember that all of the authorized telephone equipment, carrying the CE mark must be able to withstand it without damage. This is not always the case however with some low-end devices made in China, but that’s an entirely different problem. Since pulses generated by lightning are very brief, the ground connection of our assembly must be as low-inductance as possible.
It must therefore be short, and composed of heavy-duty wire (1.5 mm2 c.s.a. is the minimum). If not, the coil, composed of the ground connection, blocks the high frequency signal that constitutes the pulse and reduces the assembly’s effectiveness to nothing. Finally, please note that this device obviously has no effect on the low frequency signals of telephones and fax machines and it does not disturb (A)DSL signals either.
Monday, September 1, 2014
Simple Over Under Voltage Protection Of Electrical Appliances
This is a simple Over - Under-Voltage Protection Of Electrical Appliances. This schema protects refrigerators as well as other appliances from over and under-voltage. Operational amplifier IC LM324 (IC2) is used here as a comparator. IC LM324 consists of four operational amplifiers, of which only two operational amplifiers (N1 and N2) are used in the schema.
Over - Under-Voltage Protection Of Electrical Appliances Circuit Diagram
The unregulated power supply is connected to the series combination of resistors R1 and R2 and potmeter VR1. The same supply is also connected to a 6.8V zener diode (ZD1) through resistor R3.Preset VR1 is adjusted such that for the normal supply of 180V to 240V, the voltage at the non-inverting terminal (pin 3) of operational amplifier N1 is less than 6.8V. Hence the output of the operational amplifier is zero and transistor T1 remains off. The relay, which is connected to the collector of transistor T1, also remains de energised. As the AC supply to the electrical appliances is given through the normally closed (N/C) terminal of the relay, the supply is not disconnected during normal operation.
When the AC voltage increases beyond 240V, the voltage at the non-inverting terminal (pin 3) of operational amplifier N1 increases. The voltage at the inverting terminal is still 6.8V because of the zener diode. Thus now if the voltage at pin 3 of the operational amplifier is higher than 6.8V, the output of the operational amplifier goes high to drive transistor T1 and hence energise relay RL. Consequently, the AC supply is disconnected and electrical appliances turn off. Thus the appliances are protected against over-voltage. Thus the appliances are protected against over-voltage.
Now let’s consider the under-voltage condition. When the line voltage is below 180V, the voltage at the inverting terminal (pin 6) of operational amplifier N2 is less than the voltage at the non-inverting terminal (6V). Thus the output of operational amplifier N2 goes high and it energises the relay through transistor T1. The AC supply is disconnected and electrical appliances turn off. Thus the appliances are protected against under-voltage. IC1 is wired for a regulated 12V supply.
Thus the relay energises in two conditions: first, if the voltage at pin 3 of IC2 is above 6.8V, and second, if the voltage at pin 6 of IC2 is below 6V. Over-voltage and under-voltage levels can be adjusted using presets VR1 and VR2, respectively.
Sourced by : EFY Author : C.H. VITHALANI
Labels:
appliances,
electrical,
of,
over,
protection,
simple,
under,
voltage
Wednesday, August 27, 2014
Build a Power supply Protection Wiring diagram Schematic
Why Build a Power supply Protection Circuit Diagram. When using a regulated supply to reduce a supply voltage there is always the danger of component failure in the supply and consequent damage to the equipment. A fuse will protect when excess current is drawn, but might be too slow to cope with over voltage conditions. The values shown are for a 12 V supply being dropped to 5 V.
Power supply Protection Circuit Diagram
The trip voltage is set to 5.7 V to protect the equipment in the event of a regulator fault. The 330 ohm resistor and the 500 ohm potentiometer form a potential divider which samples the output voltage as set by adjustment of the potentiometer. The SCR is selected to carry at least twice the fuse rating. The full supply voltage is connected to the input of the regulator.
The 2N2906 is held bias off by the 10 k resistor and the SCR so that the LED is held off. If the output voltage rises above a set trip value then the SCR will conduct, the fuse will blow, and the 2N3906 will be supplied with base current via the 10 k resistor, and the LED will light up.